|
|
|
|
Wiring set for electronically regulated air-conditioning
|
|
Wiring set for electronically regulated air-conditioning
|
|
|
|
|
|
|
|
Wiring set for electronically regulated air-conditioning
PR:9AK
|
|
Wiring set for electronically regulated air-conditioning
|
|
|
PR:9AK |
|
|
1 |
4G1 971 569
|
qty: 1
Wiring set for electronically regulated air-conditioning
|
4G1 971 569
|
Wiring set for electronically regulated air-conditioning
|
lhd |
1 |
|
|
|
1 |
4G2 971 569
|
qty: 1
Wiring set for electronically regulated air-conditioning
|
4G2 971 569
|
Wiring set for electronically regulated air-conditioning
|
rhd |
1 |
|
|
|
|
|
Wiring set for electronically regulated air-conditioning
PR:9AQ
|
|
Wiring set for electronically regulated air-conditioning
|
|
|
PR:9AQ |
|
|
1 |
4G1 971 569 A
|
qty: 1
Wiring set for electronically regulated air-conditioning
|
4G1 971 569 A
|
Wiring set for electronically regulated air-conditioning
|
lhd |
1 |
|
|
|
1 |
4G2 971 569 A
|
qty: 1
Wiring set for electronically regulated air-conditioning
|
4G2 971 569 A
|
Wiring set for electronically regulated air-conditioning
|
rhd |
1 |
|
|
|
|
|
Individual parts
|
|
Individual parts
|
|
|
|
|
|
- |
|
* Corrug. tubes, T-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * ELECTRICAL * CONNECTING ELEMENTS
|
|
* Corrug. tubes, T-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * ELECTRICAL * CONNECTING ELEMENTS
|
|
|
|
|
|
3 |
8K0 973 754
|
qty: X
Flat contact housing Connection piece Air flap adjuster
|
8K0 973 754
|
Flat contact housing Connection piece Air flap adjuster
|
4 pin black |
X |
|
|
|
4 |
1J0 971 972
|
qty: X
flat connector housing Connection piece Temperature sensor Footwell vent
|
1J0 971 972
|
flat connector housing Connection piece Temperature sensor Footwell vent
|
2 pin black left a. right |
X |
|
|
|
5 |
1J0 972 923
|
qty: X
Flat contact housing with contact locking mechanism Connection piece Temperature sensor
|
1J0 972 923
|
Flat contact housing with contact locking mechanism Connection piece Temperature sensor
|
2 pin |
X |
|
|
|
6 |
1K0 972 928
|
qty: 1
Flat contact housing with contact locking mechanism Connection piece Control and display panel for air-conditioning system Climatronic
|
1K0 972 928
|
Flat contact housing with contact locking mechanism Connection piece Control and display panel for air-conditioning system Climatronic
|
16 pin black |
1 |
|