| | | | Interface boxIndividual partsfibre optic wave conductor PR:8UV,8YF, 8DZ,8UW | | Interface boxIndividual partsfibre optic wave conductor | 'MMI 2G' | | PR:8UV,8YF, 8DZ,8UW |
| | | | Interface box PR:8UW+QV0, QV3 | | Interface box | 'HEAD-UNIT' | | PR:8UW+QV0, QV3 |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | 1 | 4E0 910 769 R | 4E0 910 769 R qty: 1 interface box with software | | interface box with software | right front | 1 | |
| | | | Interface box PR:8UW+QU1, QV1,QV5,QV9 | | Interface box | 'HEAD-UNIT' | | PR:8UW+QU1, QV1,QV5,QV9 |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | (1) | 4E0 910 769 S | 4E0 910 769 S qty: 1 interface box with software | | interface box with software | right front | 1 | |
| | | | Interface box PR:8UW+QV0+ 7X8 | | Interface box | 'HEAD-UNIT' | | PR:8UW+QV0+ 7X8 |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | (1) | 4E0 910 769 S | 4E0 910 769 S qty: 1 interface box with software | | interface box with software | right front | 1 | |
| | | | Interface box PR:8UV,8YF | | Interface box | 'HEAD-UNIT' | | PR:8UV,8YF |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | (1) | 4E0 910 769 K | 4E0 910 769 K qty: 1 interface box with software PR:QU3,QV1, 7X8 | | interface box with software | right front | 1 | PR:QU3,QV1, 7X8 |
| | | | Interface box PR:8UV+7T4 | | Interface box | 'HEAD-UNIT' | | PR:8UV+7T4 |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | (1) | 4E0 910 769 L | 4E0 910 769 L qty: 1 interface box with software | | interface box with software | right front | 1 | |
| | | | Interface box PR:8DZ | | Interface box | 'HEAD-UNIT' | | PR:8DZ |
| | - | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | obligatory documentation partWhen ordering, provide vehicleidentification number. ------------------------------ | | | |
| | - | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | Only possible to determine the fitted part number by reading it using the diagnostics tester. ------------------------------ | | | |
| | (1) | 4E0 910 731 Q | 4E0 910 731 Q qty: 1 interface box with software D >> - 05.11.2007 | | interface box with software D >> - 05.11.2007 | right front | 1 | |
| | (1) | 4E0 910 732 J | 4E0 910 732 J qty: 1 interface box with software D - 05.11.2007>> - 26.05.2008 | | interface box with software D - 05.11.2007>> - 26.05.2008 | right front | 1 | |
| | (1) | 4E0 910 769 M | 4E0 910 769 M qty: 1 interface box with software D - 26.05.2008>> | | interface box with software D - 26.05.2008>> | right front | 1 | |
| | | | Individual parts | | Individual parts | | | |
| | 2 | N90 729 002 | N90 729 002 qty: 2 fillister head bolt (combi.) | | fillister head bolt (combi.) | M5X16 | 2 | |
| | 3 | N90 356 203 | N90 356 203 qty: 2 Speed nut | | Speed nut | M5X16, 6X17 | 2 | |
| | 8 | | Diagnosis interface fordata bus (Gateway) see illustration: | | Diagnosis interface fordata bus (Gateway) see illustration: | 'GATEWAY' 907-000 | | |
| | 14 | | Cross member for dash panel see illustration: | | Cross member for dash panel see illustration: | 857-000 | | |
| | 16 | 8E0 972 420 | 8E0 972 420 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 20 pinred | 1 | |
| | 17 | 4E0 973 702 | 4E0 973 702 qty: 1 flat connectorfibre optic wave conductor | | flat connectorfibre optic wave conductor | 2 pinblack | 1 | |
| | 18 | 4E0 971 086 D | 4E0 971 086 D qty: 1 Adapter cable loomDisplay unit | | Adapter cable loomDisplay unit | 1060MM | 1 | |
| | (18) | | Adapter cable loomDisplay unit see illustration: "J.." | | Adapter cable loomDisplay unit see illustration: | 035-007 | | "J.." |
| | 19 | 4E0 035 576 K | 4E0 035 576 K qty: 1 Removable housing for aerialfemale connector only to be used for: | | Removable housing for aerialfemale connector only to be used for: | 1 pointlight blueall colours | 1 | |
| | - | 4F0 972 510 | 4F0 972 510 qty: 1 Flat contact housing withcontact locking mechanismConnection pieceInterface box "CN." | | Flat contact housing withcontact locking mechanismConnection pieceInterface box | 10 pinblack | 1 | "CN." |
| | | | fibre optic wave conductor | | fibre optic wave conductor | | | |
| | 26 | 4E0 972 460 | 4E0 972 460 qty: X fibre optic wave conductor | | fibre optic wave conductor | 10000MM | X | |
| | 28 | 4E0 973 702 | 4E0 973 702 qty: X flat connectorfibre optic wave conductor | | flat connectorfibre optic wave conductor | 2 pinblack | X | |
| | 29 | N10 540 101 | N10 540 101 qty: X Connecting sleevefibre optic wave conductor | | Connecting sleevefibre optic wave conductor | | X | |
| | 30 | 4E0 972 645 | 4E0 972 645 qty: X Connecting piecefibre optic wave conductor | | Connecting piecefibre optic wave conductor | black | X | |
| | 31 | N91 057 701 | N91 057 701 qty: X corrugated pipe, in coils of10m 'order unit 10' | | corrugated pipe, in coils of10m 'order unit 10' | 3MM | X | |
| | 32 | 4E0 973 802 | 4E0 973 802 qty: 1 Flat connector housing withfibre optic bridge | | Flat connector housing withfibre optic bridge | | 1 | |
| | 36 | | Protective cap for flat insertsleeveobtain from service/workshop equipment | | Protective cap for flat insertsleeveobtain from service/workshop equipment | | | |
| | 37 | | Protective capfibre optic wave conductorobtain from service/workshop equipment | | Protective capfibre optic wave conductorobtain from service/workshop equipment | | | |
| | 38 | | Protective capfibre optic wave conductorControl unitobtain from service/workshop equipment | | Protective capfibre optic wave conductorControl unitobtain from service/workshop equipment | | | |